Ski Gate Chrono had three console test pads on its production board but no way for a spring-pin fixture to locate them reliably. The revision adds two 1.6-millimeter tooling holes and two optical alignment marks around the pads. They add no component, assembly step, or bill-of-materials line, yet they give every returned unit a repeatable mechanical connection to its serial console.
The generated schematic initially failed because its symbol library didn't contain the new mounting-hole part. After regenerating 31 symbols, the project re-read the output and checked that the three test pads, two holes, and two alignment marks had the intended footprints, that no component sat within eight millimeters, and that the board validator passed.
Debug access is a mechanical feature as much as an electrical one. If a team expects to diagnose field returns, it should put registration geometry around the test pads before releasing the board. Adding four copper-free marks during layout is far cheaper than holding probes by hand against a failed production unit.